Video Library
See digital image correlation at work, then learn to run it
Lectures, real test footage, and step-by-step VIC-3D tutorials from the engineers at Correlated Solutions. Choose the path that fits where you are.
NEW TO DIC
Discover DIC
How DIC works, who uses it, and what it looks like in real tests.
DIC Fundamentals · Applications · News & Events
ALREADY HAVE VIC-3D
Using VIC-3D
Tutorials in order, from the speckle pattern and calibration to presenting your results.
Getting Started · Speckling & Calibration · Visualizing DIC
LOOKING FOR THE LATEST?
For engineers and researchers finding out what digital image correlation can do.
Discover DIC
START HERE
A guest lecture at Oregon State University by Alistair Tofts, joined by Dr. Brian Bay, with quasi-static, microscopic, dynamic, and thermal strain examples. WATCH THE LECTURE
THEN
Dr. Michael Sutton's BSSM 2026 lecture on IMPACT, which extracts material properties directly from full-field DIC strain data, and on reconstructing stress fields under dynamic loading.
Professor Michael A. Sutton's lecture at the 20th International Conference on Advances in Experimental Mechanics, hosted by the British Society for Strain Measurement (BSSM) in Swansea, UK, 8–10 September 2026. The lecture has two parts. The first and larger part presents IMPACT (Inverse Method for Property Assessment via Correlation Techniques), a method that extracts heterogeneous material properties directly from full-field DIC strain data. It solves the equilibrium equations for the properties instead of iterating a finite element model until it matches the measurements. Sutton covers the theory and the stabilization the inverse problem needs, then shows 1D results from synthetic data and from a multi-layer specimen measured with VIC-3D. He also presents new 2D results compared side by side with finite element model updating (FEMU) on an aluminum tensile specimen. The FEMU analysis was run independently by Hubert Schreier and Ian Adkins of Correlated Solutions. The second part presents a non-parametric method for reconstructing stress fields under dynamic loading. It combines DIC-measured motion with explicit dynamic finite element analysis, so it needs no material model, and is demonstrated on a Kolsky bar test. The lecture closes with a short history of DIC. Michael A. Sutton is a Carolina Research Professor in the Department of Mechanical Engineering at the University of South Carolina, and co-founder and Chief Science Officer of Correlated Solutions. For more information, please visit correlatedsolutions.com
How full-field DIC measurements compare with finite element (FE) results.
Learn more about the fundamentals of digital image correlation (DIC) in this video featuring Correlated Solutions sales engineer, Elisha Byrne. This is the first of three in our new short course on digital image correlation. This presentation covers general principles and theories that form the foundation of DIC. In it, we cover definitions, common uses, and pattern requirements. We discuss theory on how DIC measures shapes and displacements by temporal tracking of pixel subsets, stereo-correlation of subsets, and stereo-triangulation. The latter utilizes the calibration model to perform a 3D reconstruction of the object. Strain computations are then made from the displacements of neighboring points followed by the application of a user-defined low-pass decay filter. This is how 3D DIC obtains full-field 3D shape, deformation, and strain data on any surface with a speckle pattern and imaged with two cameras.
Lectures and explainers on how DIC works.
DIC Fundamentals
Applications
Real tests, from running shoes to the Mars 2020 heat shield.
Alistair Tofts talks with NASA's Dr. Sotiris Kellas about the Mars 2020 mission and the role DIC played in developing the Perseverance rover's heat shield.
Everyone at Correlated Solutions will be glued to the live NASA feed on February 18, 2021 to witness the landing of the Mars 2020 Perseverance Rover. We are honored that our digital image correlation systems were used in the development of the heat shield – a crucial component for the Rover to enter the Martian atmosphere safely. To mark this occasion, we’re excited to present an in-depth discussion between Alistair Tofts from Correlated Solutions and senior aerospace engineer, Dr. Sotiris Kellas about the Mars 2020 mission and the role digital image correlation played. Dr. Kellas was the technical lead of the NASA Engineering and Safety Center team which supported the development of the heat shield on the Mars 2020 spacecraft.
A short look back at how NASA’s Perseverance rover's wheels were developed, including testing with digital image correlation.
Now that NASA's Perseverance Rover has started to make its way around the surface of Mars, it's a good time to look back at the development of the wheels - including cutting-edge testing with digital image correlation and other advanced photogrammetric technology.
The full interview with senior aerospace engineer, Dr. Sotiris Kellas about the Mars 2020 mission and the role of digital image correlation can be viewed here: https://www.youtube.com/watch?v=ehu-RmhICrk
Dr. Kellas was the technical lead of the NASA Engineering and Safety Center team which supported the development of the heat shield on the Mars 2020 spacecraft.
If you have any questions about how our industry-leading DIC systems can improve your research, please contact one of our sales engineers for more information.
The Kevlar vest ballistic test revisited: the original high-speed images re-presented in iris, showing what iris can do with test images captured years earlier.
To demonstrate the functionality of iris, the powerful data visualization tool that comes standard in all VIC-2D and VIC-3D digital image correlation systems, we returned to our test of a Kevlar vest receiving a bullet. Take your test images (even if they were captured years ago) to the next level with Correlated Solutions.
To find out more, contact our sales engineers today. https://www.correlatedsolutions.com/contact-us/
Here are a few more details about the system:
The VIC-3D digital image correlation system is a high-speed measurement system for full-field shape, displacements, velocities, strains, and much more. Systems with frame rates from 1,000 to 500,000 Hz are available, and configurations are customized to your applications and budget. See the VIC-3D Ultra High-Speed system page for frame rates up to 5MHz. Our systems are streamlined and integrated with supported high-speed cameras with acquisition software VIC-Snap HS, which allows the user to acquire calibration and test images with ease. Synchronized images are seamlessly acquired and saved in the correct format for fast data analysis in VIC-3D.
The VIC-3D HS system includes all the benefits of the standard VIC-3D system in addition to fully-integrated high-speed cameras. Shape, movement, and strain are tracked and computed for every data point (pixel subset) within the field of view. Since this data is calculated in three dimensions, out-of-plane displacements are measured directly, essentially eliminating bias. All calculations are done quickly and automatically with the included VIC software suite.
News & Events
Introducing the Blue Hawk, a stereo DIC system whose lens and baseline adjust to preset positions, so repeated tests can share one stereo calibration.
3D digital image correlation is a technique that relies on a precise relationship between two cameras. In a growing number of applications, repetitive testing is required, and researchers are calling on DIC to provide precise, non-contact strain and deformation measurements in successive, identical tests. In these scenarios, valuable testing time is lost to laborious but necessary camera setup and adjustments. After extensive testing and an iterative design process, we are proud to introduce the Blue Hawk system. Compared to the variety of fixed field-of-view DIC options available, the Blue Hawk system offers more adjustability without compromising convenience, so researchers can measure a wide variety of applications with minimal adjustment. Once the FOV preference is set (with easy lens/baseline adjustments to pre-determined fixed locations), the system can be used repeatedly with the same stereo calibration. When combined with the industry-leading VIC-3D software, the Blue Hawk system produces highly accurate results with an unmatched level of precision, repeatability, and convenience. Versatility is the Blue Hawk’s strongest feature. It is available with sensors from 2.4 to 24.6 Megapixels and has four adjustable baseline positions. Depending on the combination of sensor, lens, and camera position, a field-of-view range covering 40 mm to 400 mm is possible. Other important Blue Hawk features include: • A rigid, carbon-composite stereo beam, designed for repetitive testing and high calibration stability. • A powerful, fully integrated blue LED (Blue-X-Lite) which is ideal for fluorescent speckling. • Interchangeable optics with high-end lenses with locking focus and iris can be changed to quickly adjust the field-of-view. • Laser Alignment: four internal laser pointers allow easy alignment of the system with the center of the test specimen. • The versatile mounting options include tripods, or direct mounting to tensile testing machines via magnetic, column, or slot clamping. The Blue Hawk digital image correlation system from Correlated Solutions is now available. We invite you to contact one of our sales engineers for more details.
A VIC-3D training session at Clemson University's ICAR facility.
Introducing the VIC-Gimbal, automated calibration for VIC-3D, built for high-resolution cameras, small depths of field, confined or hazardous test areas, and repeated calibrations.
Introducing VIC-Gimbal: Automatic Calibration for DIC
Since its founding in 1998, Correlated Solutions has been at the vanguard of the development of sophisticated stereo camera calibration techniques for all kinds of applications all around the world.
As technologies and testing needs evolve, new challenges have emerged that can impact successful calibration for digital image correlation. To meet a specific set of challenges faced by our customers, the engineers at Correlated Solutions have developed a new method for stereo camera calibration.
Designed for precision, automated calibration of VIC-3D systems, the VIC-Gimbal provides a unique solution for researchers working with high-resolution cameras, small depths-of-field (DOF), confined/hazardous testing areas, and iterative testing scenarios requiring programmable, repeatable calibration.
New products, training and announcements.
Step-by-step tutorials for VIC-Snap, VIC-3D, and iris.
Using VIC-3D
START HERE
Getting Started, in order
Begin with the speckle pattern, then follow the five-part series from calibration to visualization. Each part picks up where the last one ends.
Why the speckle pattern matters so much to DIC results, what a good pattern needs, and the common ways to apply one.
This video covers the fundamentals of creating an effective speckle pattern for digital image correlation. In digital image correlation, one or more cameras take a series of images as a specimen deforms. Measurements are taken by precisely analyzing the position of unique groups of speckles on the surface of the object as it moves through successive images. Using an optimal speckle pattern is one of the most important factors in reducing measurement noise and improving overall DIC results, therefore, understanding the requirements of an ideal speckle pattern and how to apply one to a specimen is a vital part of DIC. In this tutorial, we briefly discuss the theoretical background of DIC, then we’ll cover general speckle pattern requirements and outline some common application methods. Please note that every test is different and much depends on the unique parameters of specific test conditions. If you have any questions, please contact our Sales or Support Teams who are always ready to help.
Part 1 of 5. Calibrating a stereo DIC system in VIC-Snap and VIC-3D using laser-marked calibration targets.
This is the first of a series of five tutorial videos that cover the basics of using the VIC-3D digital image correlation system. This first video covers calibration for 3D DIC using the new laser-marked targets from Correlated Solutions. Please note that every test is different and much depends on the unique parameters of specific test conditions. This calibration was performed without using linear polarizers on the lenses and the light source, which can help reduce reflections making the calibration that much easier. If you have any questions, please contact our Support Team who are always ready to help. Support Team Support Portal Exceed Universal Test Frame from MTS
Part 2 of 5. Capturing test images in VIC-Snap during a tensile test on a plastic dog bone specimen, with tips on VIC-Snap's advanced options along the way.
This is the second of five tutorial videos that cover the basics of using the VIC-3D digital image correlation system from Correlated Solutions. This video covers best practices for capturing test images in VIC-Snap. In it, we’ll run a simple tensile test on a plastic dog bone in the MTS Exceed 43 test frame, capture images of the test with VIC-Snap, and get ready to import them into the VIC-3D system. Along the way, we’ll review some of the advanced options in VIC-Snap and cover some basic tips and tricks.
Part 3 of 5. Importing calibration and test images into VIC-3D, then defining the area of interest (AOI) and choosing subset and step size before you run the analysis.
This is the third of five tutorial videos that cover the basics of using the VIC-3D digital image correlation system from Correlated Solutions. This video reviews importing calibration and test images into the VIC-3D software. It also covers defining an area of interest (AOI), determining optimal step and subset size parameters, and it outlines general tips to remember as you prepare to analyze your DIC data. If you have any questions, please contact our Support Team who are always ready to help. Support Team Support Portal Exceed Universal Test Frame from MTS Previous videos in this series: Basic Calibration in VIC-Snap Test Image Acquisition in VIC-Snap
Part 4 of 5. Running a basic analysis in VIC-3D, then viewing, exporting, and post-processing the results with the tools most analyses rely on.
This video covers basic 3D digital image correlation analysis using the VIC-3D software from Correlated Solutions. It describes a variety of options for viewing and exporting data and reviews some of the most common post-processing tools and best practices that are applicable for most analyses. The fourth in our tutorial series covering a basic example of digital image correlation using VIC-3D, this video picks up after the Basic Calibration in VIC-Snap, Test Acquisition in VIC-Snap, and Importing Images and Preparing for Analysis videos (links below). It assumes you have captured a set of calibration images with an acceptable score, gathered a set of test images in VIC-Snap, drawn an area of interest, determined optimal subset and step sizes, and run an initial analysis. Of course, many of the next steps depend on individual testing parameters and desired results. This test uses data from a tensile test of a dog bone in an MTS test frame that we completed in an earlier video. If you have any questions, please contact our Support Team who are always ready to help. Support Team Support Portal Exceed Universal Test Frame from MTS Previous videos in the series: Basic Calibration in VIC-Snap Test Image Acquisition in VIC-Snap Importing Images and Preparing for Analysis
Part 5 of 5. Building pages of 2D, 3D, and extraction plots in iris, working with timelines and text, and exporting a high-resolution PDF and video.
This tutorial introduces the data visualization potential of the iris graphics engine which now comes standard with every Correlated Solutions digital image correlation system. This tutorial is designed to help guide a novice user through the process of creating and exporting basic pages with 2D plots, 3D plots, and extraction plots. It covers working with timelines, text boxes, and other objects in iris. The tutorial ends with an explanation of how to export a high-resolution pdf and video. This is the fifth in our series covering a basic example of digital image correlation using VIC-3D. It picks up after the first four of our basic DIC videos (linked below). It assumes you have captured a set of calibration images with an acceptable score, gathered a set of test images in VIC-Snap, drawn an area of interest, determined optimal subset and step sizes, run an analysis, and extracted some data using the inspector tools. For more advanced iris users, we have an ongoing tutorial series which covers specific aspects of this powerful tool. Explore the whole playlist. And as always, our US-based support team is ready to help if you have any questions. Support Team Support Portal Exceed Universal Test Frame from MTS Previous videos in this series: Basic Calibration in VIC-Snap Test Image Acquisition in VIC-Snap Importing Images and Preparing for Analysis Basic DIC Analysis in VIC-3D
Speckling & Calibration
Calibration targets, setup and the VIC-Gimbal.
Why the speckle pattern matters so much to DIC results, what a good pattern needs, and the common ways to apply one.
This video covers the fundamentals of creating an effective speckle pattern for digital image correlation. In digital image correlation, one or more cameras take a series of images as a specimen deforms. Measurements are taken by precisely analyzing the position of unique groups of speckles on the surface of the object as it moves through successive images. Using an optimal speckle pattern is one of the most important factors in reducing measurement noise and improving overall DIC results, therefore, understanding the requirements of an ideal speckle pattern and how to apply one to a specimen is a vital part of DIC. In this tutorial, we briefly discuss the theoretical background of DIC, then we’ll cover general speckle pattern requirements and outline some common application methods. Please note that every test is different and much depends on the unique parameters of specific test conditions. If you have any questions, please contact our Sales or Support Teams who are always ready to help.
A complete guide to the VIC-Gimbal: software requirements, specifications, and a full calibration from start to finish in VIC-Snap, VIC-3D, and iris.
This video guide to the VIC-Gimbal covers software requirements, technical specifications, and a basic test case showing a full calibration from beginning to end using VIC-Snap, VIC-3D, and the iris visualization workspace. If you have any questions about the VIC-Gimbal or any other questions, comments, or concerns about your Correlated Solutions system, please contact our Support Team: support@correlatedsolutions.com
The video version of the DIC + Thermal Imaging application note: calibrating infrared and white-light cameras together, through to combined DIC and IR visualization in iris. Shown in VIC-3D 10.
Recently, we conducted a controlled test featuring the infrared module in VIC-3D 10 to demonstrate an updated procedure for calibrating IR and white light cameras. To better illuminate this new, more effective method, this video version of the DIC + Thermal Imaging Application Note covers the whole process from Calibration to DIC/IR visualization using iris in VIC-3D 10.
Episode 1. Watch the iris project behind the DIC + Thermal Imaging application note being built start to finish, at your own pace and with minimal narration.
Visualizing Digital Image Correlation is a new series that provides a unique window into advanced features and workflows using the iris graphics workspace within digital image correlation software from Correlated Solutions. Each video provides our customers the opportunity to watch the production of an iris project - one that is featured in a corresponding promotional video or application note - at their own pace with minimal instruction.
Episode 1 corresponds to the DIC + Thermal Imaging Application Note which covers the updated calibration procedure for VIC-3D 10 and thermal imaging (IR) cameras.
Find that video here: https://youtu.be/N_6dJ5_nQos If you have questions about any part of this process, please contact our Support Team directly: https://www.correlatedsolutions.com/support For more information on how the idea for this series emerged, check out this blog post: https://www.correlatedsolutions.com/recent-news/visualizing-digital-image-correlation Or the iris page on our website: https://www.correlatedsolutions.com/iris
Episode 2. Producing a dynamic calibration report from text, graphics, and image sequences in iris, using the project behind the VIC-Gimbal application note.
Visualizing Digital Image Correlation is a new series that provides a unique window into advanced features and workflows using the iris graphics workspace within digital image correlation software from Correlated Solutions. Each video provides our customers the opportunity to watch the production of an iris project - one that is featured in a corresponding promotional video or application note - at their own pace with minimal instruction.
Episode 2 corresponds to the VIC-Gimbal Application Note and shows the process of producing a dynamic calibration report using text, graphics, and image sequences in the iris workspace within VIC-3D.
The full VIC-Gimbal Guide video is here: https://www.youtube.com/watch?v=ldnLB-6-dso If you have questions, please contact our Support Team directly: https://www.correlatedsolutions.com/support For more information on how the idea for this series emerged, check out this blog post: https://www.correlatedsolutions.com/recent-news/visualizing-digital-image-correlation
Episode 3. Building a report from one of the pre-installed iris templates, then modifying the template into a branded presentation inside VIC-3D.
The Visualizing Digital Image Correlation series provides a unique window into advanced features and workflows using the iris graphics workspace within digital image correlation software from Correlated Solutions. Each video provides our customers the opportunity to watch the production of an iris project - one that is featured in a corresponding promotional video or application note - at their own pace with minimal instruction. Episode 3 examines the use of templates in iris for creating professional reports based on your DIC data. It shows the process of producing a dynamic report using one of the pre-installed templates and then covers how to modify these templates to create a branded presentation directly within VIC-3D. Episode 3 uses the all-new dark mode and features a range of new templates and other improvements to the iris workspace.
Building reports and presentations in iris. Also holds the five-part iris Training Series.
Visualizing DIC
An introduction to VIC-3D 11, the current release, with a focus on easier FEA comparison and a new feature for running Python scripts inside the VIC-3D workspace.
We are proud to announce that VIC-3D 11, the latest release from Correlated Solutions, is now available. An unparalleled 3D DIC analysis software program with powerful new features, VIC-3D 11 has been designed to enhance the user’s experience while improving data analysis with a focus on making FEA comparison easier and more accurate. The all-new vicpyx extension feature allows users to execute Python scripts within the VIC-3D workspace, eliminating the need to use cumbersome command prompts.
To take advantage of a special upgrade offer, contact our Sales Team today!
#digitalimagecorrelation
Running the Polar Coordinates extension in vicpyx to express displacement and strain as radial and tangential (hoop) components, shown on a speckled paper ring. Shown in VIC-3D 11.
Standard DIC analysis produces displacement and strain data in Cartesian (x, y, z) coordinates. This works well for many applications, but certain geometries and loading conditions are better understood in alternative coordinate systems.
For turbine blades, flywheels, brake rotors, and other rotating machinery, understanding radial versus tangential behavior is critical. A displacement that appears as a complex combination of X and Y components in Cartesian coordinates becomes a clear radial expansion or tangential shift in polar coordinates.
Pressure vessels, pipes, and O-ring seals naturally deform in radial patterns. Analyzing hoop strain (tangential) separately from radial strain provides direct insight into material behavior and failure modes that would be obscured in Cartesian representation.
Further, the stress field around circular holes follows polar patterns. Expressing strain in polar coordinates aligns your measurements with analytical solutions and textbook formulas, making validation and comparison straightforward.
To demonstrate the use of the Polar Coordinate extension in VIC-3D 11, we devised a simple test using a speckled ring printed on a piece of paper variously crinkled over 5 images. To follow along, download the test images and project file (containing calibration information) by clicking here: https://www.correlatedsolutions.com/downloads
Note: to use the Polar Coordinate extension and the other vicpyx extensions, Python must be installed. Click here for more information: https://www.correlatedsolutions.com/recent-news/python-dic-introducing-vicpyx
Please see other iris tutorials and our Visualizing DIC series for more details about the iris visualization workspace. https://www.youtube.com/watch?v=QVDga5aq3JA&list=PLKk1tDmnghhe4TrT-yJ-ZekksC1R2UCgq
If you have any questions about this document or any other questions, comments, or concerns about our software, please visit our website: https://www.correlatedsolutions.com/support
The powerful vicpyx feature is available exclusively in VIC-3D 11. Contact one of our Sales Engineers for information on updating your software. https://www.correlatedsolutions.com/contact
Installing the vicpyx extensions, which run Python scripts on full-field DIC data from inside VIC-3D. Ready-made extensions need no coding. Shown in VIC-3D 11.
Introduced in VIC-3D 11, the vicpyx update builds upon the previous VIC-Py framework for deploying Python to manipulate, transform, and export DIC measurement data for application-specific requirements. Whether computing derived quantities, applying coordinate transformations, or combining multiple variables into new metrics, the vicpyx framework handles the complexity so researchers can focus on the engineering. Fully integrated with VIC-3D, vicpyx allows users to apply custom calculations to full-field data by executing Python scripts directly.
The vicpyx extensions are powered by Python, but you don't need to write code to benefit from them. A library of ready-to-use extensions covering common research needs is installed with VIC-3D. Further, additional extensions can be edited and shared among colleagues or obtained from Correlated Solutions. Once Python is installed, simply select an extension from the menu, configure the options, and run.
For users with Python experience, the framework is fully open. Here are a few of the possibilities available to researchers using vicpyx:
-Create new variables computed from existing measurements
-Transform coordinate systems to match your analysis needs
-Extract line profiles and point data along custom paths
-Export to any format required by downstream tools (FEA software, custom analysis pipelines, reporting systems)
-Leverage any Python library - NumPy for numerical computing, SciPy for advanced algorithms, or domain-specific packages
Extensions work directly within the VIC interface. Results appear alongside your original data, can be visualized with the same tools, and are saved with your project. There is no need to export data, process it externally, and re-import results.
In upcoming application notes, individual extensions will be covered in greater detail.
The powerful vicpyx extensions feature is available exclusively in VIC-3D 11. Contact one of our Sales Engineers at sales@correlatedsolutions.com or https://www.correlatedsolutions.com/contact for information on updating your software
Find out more about VIC-3D 11 here: https://www.correlatedsolutions.com/vic-3d
Release walkthroughs, labeled by version.
What’s New in VIC-3D
Looking for something specific?
Browse all 60 videos, newest first, or filter by category.
Sales engineer Elisha Byrne explains the principles behind DIC: subset tracking, stereo triangulation, calibration, and how strain is computed from displacement. Part 1 of a three-part short course.
Learn more about the fundamentals of digital image correlation (DIC) in this video featuring Correlated Solutions sales engineer, Elisha Byrne.
This is the first of three in our new short course on digital image correlation. This presentation covers general principles and theories that form the foundation of DIC. In it, we cover definitions, common uses, and pattern requirements. We discuss theory on how DIC measures shapes and displacements by temporal tracking of pixel subsets, stereo-correlation of subsets, and stereo-triangulation. The latter utilizes the calibration model to perform a 3D reconstruction of the object. Strain computations are then made from the displacements of neighboring points followed by the application of a user-defined low-pass decay filter. This is how 3D DIC obtains full-field 3D shape, deformation, and strain data on any surface with a speckle pattern and imaged with two cameras.